Canford

www.canford.co.uk

42-632 EMO REMOTE PANEL CR32

each (ex. VAT) 1+
Price £ 92.00
EMO REMOTE PANEL CR32

Description

EMO AC MAINS POWER SWITCHING SYSTEM

A unit for the switching of audio or other systems that require to be powered up and down in a particular sequence, the up (on) sequence is the mirror image of the down (off) sequence. Instructions to initiate the sequence are input by a four digit code on a keypad either on the master unit, or on a separate keypad in a remote location (1U rackmount and 2-gang electrical versions available). The code ensures that only authorised personnel can operate the system. A fully equipped system can have ten sequentially delayed outputs. The master unit houses within a 2U rack mounting case all the control electronics for a fully equipped system, the keypad inputs, slave unit control outputs and power switched outputs 1 and 2. Output 2 in the master unit and all slave outputs are rated at 32 amps.

Applications include: theatre sound, touring systems, recording studios, audio visual, broadcasting systems, discotheques, night clubs and computer systems.

Upon entry of the correct combination (code), the code accept LED (marked ‘ON’) will illuminate, after approx 10 secs output 1 and output 1LED will turn on. This sequence will continue until all connected outputs have latched on. During the turn-on sequence no ‘OFF’ code will be accepted. Once the ‘ON’ cycle has been completed, entry of the correct combination (code) will start the turn-off sequence i.e. turn-on in reverse. As with the ‘ON’ sequence, the ‘OFF’ sequence will not accept an ‘ON’ code until the system has completed its cycle. On mains power-up or after loss of power the system will reset to ‘OFF’.

Includes a “fire alarm” interface as standard that is activated by opening contacts which trigger the controlled turn-off sequence.

Technical Specification:

CM6 Master unit:

Output rating:Output 1: 10 amps (1kw audio)
Output 2: 32 amps (5kw audio)
Inputs/outputs:Power in and outs on rail mounted terminal blocks (5 ways per output). Slave and remote control by barrier strip
Front panel:Six digit keypad. Mains available neon. ‘ON’ and ‘OFF’ LEDs. Output 1 and 2 ‘ON’ LEDs. Facility 13A socket outlet
Rear panel:Rail connectors for power in/out. Barrier strip for slave control. Barrier strip for remote panel connections. Overide switch (turns contactors ON)
Internal:Coding plugs for combination setting. Link to disable internal keypad when using remote keypad panel (both panels can be used in parallel if required). Switches to allow instant UP/DOWN, (this option can be useful during system installation). Power switching by contactor
Dimensions:2U × 19” × 250mm.

CS6 Slave unit:

Output rating:32 amps (5kw audio)
Front panel:Mains available neon. Output ‘ON’ LED. 13A socket outlet.
Rear panel:Rail connectors for power in/out. Barrier strip control input. Override switch (turns contactor ON).
Dimensions:2U × 19” × 250mm.

CR6 + CR32 Remote Panels:

Panel:Six digit keypad. ‘ON’ and ‘OFF’ LED.
Connections:Barrier strip.
Cabling:9 core 0.22mm²
Dimensions:CR6 - 1U × 19” × 65mm.
CR32 - 146mm x 86mm (2-gang electrical plate).

Ask a question

Please select the appropriate department from the dropdown list and enter your question providing as much relevant detail as possible.

(Fields marked * are required)

  1. UK Sales

    1. 08.30 - 17.30 UK time
    2. Telephone Number Tel: +44 (0) 191 418 1122
    3. Fax Number Fax: +44 (0) 191 418 1123
    4. e-mail address E-mail: sales@canford.co.uk
  2. International Sales

    1. 08.00 - 17.30 UK time
    2. Telephone Number Tel: +44 (0) 191 418 1133
    3. Fax Number Fax: +44 (0) 191 418 1134
    4. e-mail address E-mail: international@canford.co.uk
  3. Technical Support

    1. 09.00 - 17.30 UK time
    2. Telephone Number Tel: +44 (0) 191 418 1144
    3. Fax Number Fax: +44 (0) 191 418 1145
    4. e-mail address E-mail: techsupport@canford.co.uk