DTRS wiring convention
Many 8 channel Digital Tape Recorders are wired to this standard. To simplify connection to other equipment Canford stock a range of ready made 25pin D-Sub Breakout Cables wired to the Tascam DTRS standard.
| Channel |
Pair Colour |
Pinout |
|
| |
|
24 |
Hot |
| 1 |
Brown |
12 |
Cold |
| |
|
25 |
Screen |
| |
|
10 |
Hot |
| 2 |
Red |
23 |
Cold |
| |
|
11 |
Screen |
| |
|
21 |
Hot |
| 3 |
Orange |
9 |
Cold |
| |
|
22 |
Screen |
| |
|
7 |
Hot |
| 4 |
Yellow |
20 |
Cold |
| |
|
8 |
Screen |
| |
|
18 |
Hot |
| 5 |
Green |
6 |
Cold |
| |
|
19 |
Screen |
| |
|
4 |
Hot |
| 6 |
Blue |
17 |
Cold |
| |
|
5 |
Screen |
| |
|
15 |
Hot |
| 7 |
Violet |
3 |
Cold |
| |
|
16 |
Screen |
| |
|
1 |
Hot |
| 8 |
Grey |
14 |
Cold |
| |
|
2 |
Screen |